Table 4 Optimal model coefficients of anterior chamber depth regression

From: Distribution of ocular biometric parameters and optimal model of anterior chamber depth regression in 28,709 adult cataract patients in China using swept‐source optical biometry

Model Unstandardized Coefficients Standardized B t Sig.
B Std. Error
(Constant) -0.522 0.091   -5.746 < 0.001
LT -0.623 0.004 -0.621 -166.028 < 0.001
AL 0.064 0.001 0.348 91.727 < 0.001
WTW 0.249 0.004 0.251 62.288 < 0.001
Sex -0.121 0.003 -0.131 -35.275 < 0.001
Km 0.040 0.001 0.150 37.063 < 0.001
CCT 0.471 0.046 0.037 10.180 < 0.001
Age 0.001 0.000 0.030 7.825 < 0.001
  1. ACD anterior chamber depth; LT lens thickness; AL axial length; WTW white to white; Km mean keratometry; CCT central corneal thickness; Std. standard
\